Finished Goods Warehouse
The Finished Goods warehouse has an old self-supporting roof structure that shows many signs of corrosion, there are visible holes in the roof. It is recommended that this structure is replaced by a new one similar to the fulls warehouse.
Empty Bottles Warehouse
The roof structure of the Empty Bottles warehouse, similarly to the Fulls Warehouse, has recently been replaced with roof trusses and it is observed to still be in good condition. No repairs or replacement necessary.
Logistics Meeting Room
The Logistic Meeting room has a new roof and is observed to be in good condition. The small warehouse next to it has been affected by the cyclones and part of its self-supporting roof is missing due to the wind.
Un/Loading Bay – North
This section was recently rebuilt, the roofing sheeting, structural elements and gutters are new. Some problems were noted after the cyclone, including the ridge cap that was affected; a small section disintegrated from the attachment point.
Un/Loading Bay – South
This section of the Un/Loading bay was not rebuilt and during the last cyclone the ridge cap was blown off by the wind leaving an opening thus allowing water to enter through this open area to the operation zone.
Change Rooms
Some of the roof sheets of the Change Rooms have been replaced but the structural elements remained the same. The steel elements show signs of corrosion but are not severe. They must be treated against corrosion.
Old Chibuko House
The roof structure of the Old Chibuko House was recently re-built and changed from wood to steel trusses. There is no rainwater collection system through gutters.
Raw Materials Warehouse
The Raw Materials Warehouse was also recently re-built and changed from wood to steel trusses, but the gutters were not rehabilitated.
Water Treatment Plant
The Water Treatment Plant is functional and shows no signs of damage. The roof structure and roof sheets are in good condition and repairs are not necessary.
Silos Building
The silos building has a concrete roof slab and the waterproofing is in poor condition. There are signs of accumulated humidity, some portions are raised with air pockets and are loose.